完整假牙制造中的边界成型最佳材料

凭证下颌是缺少所有牙齿的上(上颌骨)或下颌骨的条件。在医疗实践中,可以通过放置完整的义齿来治疗。
以前的研究已经指出了边界的应用成型程序(或功能性成型)导致压力溃疡(褥疮)和软组织变形的显着较少情况,因此在休息和功能下增加假体的保留和稳定性。Since there are many factors that affect the optimal treatment, such as anatomical structures (i.e. muscles, muscular and soft-tissue gripping) and the asymmetry between the left and right halves of upper and lower jaws, it is important that special care is taken to determine the depth, as well as the width of the tissue where the teeth would normally be nested (gingivobuccal sulcus). With border molding, it is possible to determine those, however, the accuracy of the impression would still largely depend on the materials used in the procedure.
在他们的研究中,在开放式访问,同行评审学术期刊上发表Folia Medica.,Dobromira Shopova博士和Plovdiv医科大学(保加利亚)的Diyan Slavchev教授试图评估和确定两种不同的边界成型印模材料组的准确性:热塑性和弹性体。他们检查了四种不同的品牌:救济功能(用于边界成型的添加硅胶),STA-SEAL F(用于边界成型的冷凝硅胶),GC ISO功能棒(用于边界成型的合成树脂),克尔印模复合复合绿色棍子用于边界成型。
为了执行他们的研究,团队应用Dobromira Shopova博士的临床方法测量负压在边界成型过程之后,在伪造上颌上称为真空测量技术。它们还从带腭适配器的光固化底板上组装了特殊的自定义托盘。这是一个900,7毫米的金属适配器,固定在腭坡上的中线。为了创造和测量负压,它们使用了一个组合的压力泵。最大值为正压和-1条用于负压的3条。
- 所有材料后面的工作协议:
- 沿各个托盘边缘涂抹印模材料;
- 插入,位置和执行Herbst功能测试;
- 等待材料的弹性或硬化;
- 组装负压测量的临床单元;
- 测量自定义托盘与假体场之间创建的负压,然后记录结果;
- 从患者的嘴里释放单个印模托盘。

两种热塑性材料之间观察到统计学上的显着差异:GC ISO功能棒和印模复合生坯。在其他材料组之间没有观察到统计学上显着的差异。
在假体场和自定义托盘之间产生的测量平均负压值,显示每个患者的近似值-0.05至-0.1巴。这表明假体场的解剖学特征非常重要。
总之,在临床条件下,负压的定量测量完全可能。用于边界成型的热塑性材料仅沿着定制托盘的边缘保持并形成。然而,硅树脂印象材料不会仅在定制托盘的边缘上延伸,而且在肺泡脊上展示它们的优越的操纵品质和准确性边界成型。
进一步探索
用户评论